The assumption
City heat plans tend to start from one belief: built-up land is the hottest surface in town. Cooling budgets, tree planting and cool-roof drives all get aimed on that basis.
The method
Land surface temperature from Landsat 8 was split by land cover, and heat island intensity was measured as built-up against its surroundings, both as a mean and at the hot tail. For validation, MODIS MOD21A1D was chosen over MOD11A1, since MOD11A1 has a documented cold bias of 3 to 5 K over semi-arid ground. VIIRS VNP21A1D is the cross- check from a second sensor.
What it found
In Pune before the monsoon, built-up land was consistently cooler on average than the surrounding grassland, so the mean heat island intensity came out negative. The hottest built-up pixels still ran above their surroundings. That makes physical sense once the morning overpass is taken into account, because dry grassland heats up fast.
Worth noting
Landsat passes in the morning, so this is a daytime picture. Night-time heat, when built-up land holds heat longest, needs a different sensor.
How Latent can help
Surface temperature maps by season, heat island figures by ward or land cover, and a list of hotspots, so heat money goes where the heat is. This suits municipal corporations writing heat action plans, smart city teams and developers.